Combined Generator Power Management with Portable Battery Pack: All-In-One

Transform any diesel generator into a smart hybrid powerhouse with our all-in-one Generator Management and Portable e-Generator unit. Whether plugged in for automated DG optimization or unplugged for silent, high-efficiency portable power.

Plug-In to Optimize Diesel Generator

Transform traditional diesel setups into high-efficiency hybrid systems. Unlock major operational savings, zero downtime, and eco-friendly performance with our compact, battery-integrated retrofit solution.

Un-Plug to Use as Portable e-Generator

Deploy plug-and play lightweight portable e-Gen. Silent operation with patented power quality control for sensitive loads, and a 1.5x Turbo Power mode for demanding loads like motors and pumps without over sizing

Key Features

The world’s leading PhDs spent the last 10 years building out, from the ground up, the most advanced diesel generator power management unit in the industry. Here are some of the main highlights of our proprietary and patented technology, designed, developed, and made in Canada:

Massive increase in energy efficiency

Smart Generator Start/Stop Control

Seamless 0ms Industrial UPS

Available in 1ph/3ph 5kW-45kW

IP65 waterproof rated

-40°C to 60°C ambient temperature range

Zero Downtown for Generator Maintenance

Remote Monitoring / Smart App

Fast Charging Solar / DG / EV / Grid

Energize many loads (120V & 240V)

2X Power Automatic Turbo Mode

Smart Start for Motor Inrush Current

Technical Specifications

Inverter

Continuous Output Power

10kW – Bidirectional

Turbo power mode Power

15kW – for 30 sec

Output voltage

240V split phase (±120V)

Charge current

42 Arms, 65Asurge

Efficiency %10-%100 load

95-97%

Hybrid Operation mode

Online UPS, DG optimizer

Output Ports (or PV spec)

2 x 120V, 2 x 240V

Battery

Technology

Super capacitor, LFP

Capacity

5kWh - 15kWh expandable

Voltage

51.2V nominal (47V – 55V)

Charging Cycles

Up to 20,000 cycles

Mechanical

Net Weight:

90kg / 198 lb

Dimensions (WxDxH)

60x60x68cm / 23x23x26in

Download the Full Data Sheet Here

Key Benefits

Connect and Save
  • Charge from Grid/EV level 2/Diesel Gen
  • Programmable and Ultra Fast Charge options
  • Autonomous Optimization of Diesel Gen 
  • Zero downtime for DG service and refuel
  • Silent Operation 
  • Less Co2 Emission
Return on Investment as low as 2 years considering:
  • Running Costs
  • Service Costs 
  • Bat degradation
  • Initial Investment Interests
Reduce maintenance and service costs by up to 10x
  • Longer intervals between services 
  • Reduced component failure
  • DG life time extension
Lower fuel consumption by up to 5x
  • JoulePack supplies the load at 97% efficiency
  • Uses the generator at full power for maximized efficiency
  • Reduced transportation cost with fuel saving
  • Reduced cost of taxes/handling and distribution costs
Portable power suply
  • Plug and Play 
  • Unplug and use as Secondary Onsite ESS
  • Improve Load Power Quality
  • Advance Light Load Efficiency Booster
Energize any kinds of Loads
  • 1.5x Power Auto Turbo Mode
  • Smart Start for Motor Inrush Current
  • Single phase: (120V)/split phase (240V) 
  • Three Phase: unbalanced loads (120V) / (208V)
Smart Digital Systems
  • Data Logging and monitoring
  • Remote DG Status Monitoring 
  • Smart Energy Management 
  • Remote Manage and Control
Advanced Patented Technology
  • Safe and Long life Batteries
  • Agnostic to Energy Storage System
  • Optimized Cost/Efficiency/Volume/Thermal
  • Bidirectional and Scalable Conversion
  • North American complaint
Optional Features
  • Adding solar panels(PV) to further reduce the fuel consumption
  • Improve sensitive load power Quality 
  • Customized Energy management settings based on user preference
  • Advanced remote monitoring (Fuel, Power, battery health, generator running time/cycles, etc.)
  • Optimum ESS sizing based on the exact real field requirements such as site location, maintenance intervals, load profile, generator efficiency, etc.

Easy Installation and Operations

Step 1

Cut the existing cable between the diesel generator and its localload.

Step 2

Install a male plug on the local load cable, install a female plug on the generator side.

DG Optimization Mode

Plug both the generator and load cables into the eGen unit → Hybrid operation and battery-assisted DG optimization and eGen Charging

Separate Diesel and e-Gen (Portable Use)

Pug the load cable directly into the DG Cable → Use DG for local loads and e-Gen as a secondary portable power supply

Diesel Generator Use Cases

Telecommunication

  • Remote telecom towers and repeater stations
  • Off-grid mobile communication hubs
  • Disaster recovery network infrastructure

Construction & Industrial Sites

  • Oil & gas sites with Electrical Submersible Pumps (ESPs)
  • Remote construction and mining operations
  • Infrastructure projects with shifting power needs

Lighting & Security

  • Portable light towers
  • Temporary or mobile surveillance systems
  • Security trailers in isolated locations

Events & Film Production

  • Portable light towers
  • Temporary or mobile surveillance systems
  • Security trailers in isolated locations

Emergency Services & First Response

  • Support for home-based patients during grid outage
  • Firefighting units and emergency shelters
  • Temporary medical units and field hospitals

Government & Military

  • Remote government infrastructure and service sites
  • Mobile military bases
  • Border posts and surveillance infrastructure

Transport & Logistics

  • 24/7 Cardlock fuel stations and service bays
  • Portable Roadside EV Charging
  • Refrigerated trailers needing silent standby

Off-grid Sites

  • Weak-grid rural areas
  • Remote campsites and eco-lodges
  • Mobile power for RV parks and van-life hubs

Get In Touch to Experience Power Management Like No Other

Contact us
Contact us